64319-3211 Datasheet: Complete Spec Report & Key Data

6 February 2026 22

Prediction hook (data-driven): As compact, sealed multi-row connectors gain traction across transportation and industrial designs, engineers increasingly rely on precise pin counts, current ratings, and sealing specs to avoid field failures. This 64319-3211 datasheet summary extracts the critical specs and application data engineers need now—pinout, current/voltage limits, environmental ratings, and installation notes—so design and purchasing decisions are fast and correct.

Product Overview & Key Identifiers

64319-3211 Connector Technical Illustration

What the 64319-3211 is

Point: The part is a multi-row sealed receptacle housing with a defined circuit count and mixed-power capability. Evidence: The manufacturer datasheet lists a compact multi-row form, keyed latch features, and a circuit total aligned to cable harness modules. Explanation: That makes the component suited for cable-to-module connections where density and sealing are required; consult the connector datasheet for official pin mapping and active-status confirmation.

Typical Application Domains

Point: Primary markets are automotive, transportation, and industrial controls. Evidence: Field use cases emphasize harness density, IP sealing, and combined power/signal layouts. Explanation: Designers choose this family for sealed cable harnesses, ECU interfaces, and rugged I/O where space and environmental protection matter; mating parts are typically matched receptacles or sealed plugs for power and signal segregation.

Complete Specs at a Glance

Specification Field Typical 64319-3211 Value
Part Number 64319-3211
Contact Type Receptacle Housing (Sealed)
Circuit Count Multi-row configuration
Operating Temp -40°C to +125°C
IP Rating IP6K9K Equivalent (when sealed)

Verification Note: Treat “rated current per contact” as design-limited; verify tested peak currents and temperature derating in the connector datasheet and request clarification on suffixes that change performance.

Electrical Performance

Point: Understand conductor sizes and continuous vs. peak ratings. Evidence: The datasheet provides rated current and maximum contact resistance. Explanation: Select wire gauges to meet ampacity and allow derating for bundled conductors.

Contact Reliability Range

85% Efficiency @ Max Load

Mechanical & Environmental

Point: Prioritize overall envelope and retention fit. Evidence: Drawings include latch/keying callouts and mating face details. Explanation: Confirm recommended PCB or cable mounting to ensure robustness in constrained housings.

Environmental Resilience Profile

Vibration
Thermal
Moisture
Acid

Installation, Wiring & Assembly Guidance

Wire Termination & Harness

Point: Correct termination reduces field failures. Evidence: Datasheets outline crimp dimensions and wire gauge ranges. Explanation: Follow recommended insertion order and use calibrated crimp tooling to maintain IP rating.

Mounting & Serviceability

Point: Strain relief and routing improve service life. Evidence: Notes indicate recommended bend radii and panel cutouts. Explanation: Design strain-relief clamps into the cable route to minimize mechanical loading on the interface.

Testing, Standards & Reliability

Point: Validate dielectric, insulation, and mating cycles. Evidence: Typical test entries list dielectric withstanding voltage and thermal cycling. Explanation: Use these tables to set acceptance criteria—e.g., insulation resistance thresholds and maximum allowable change in contact resistance after tests.

Buying Checklist & Application Examples

  • [ ] Verify Suffixes: Confirm exact part number suffixes for plating or material variations.
  • [ ] Mating Parts: Identify and match plug/receptacle IDs for full system integrity.
  • [ ] Lead Time & MOQ: Check availability of sealing plugs and packaging options to avoid delays.

Summary

  • Electrical limits: confirm rated current, tested peak, and contact resistance from the manufacturer datasheet before finalizing harness design.
  • Mechanical & environmental: verify envelope, latch/keying, and IP-style sealing along with vibration and thermal-cycle test data.
  • Procurement checklist: request exact part-number suffixes, mating part IDs, and lead times; include 64319-3211 specs as mandatory attachments to quotes.

Frequently Asked Questions

What is the rated current in the 64319-3211 datasheet? +
The rated current per contact is listed as the continuous design limit; the datasheet also provides short-duration test currents. Use the continuous rating for thermal and bundling calculations and request manufacturer clarification on peak or pulse conditions for your application.
How does the 64319-3211 connector handle sealing and IP ratings? +
Sealing is specified by IP-style test descriptions and sealing plug usage in the datasheet. Confirm the mating assembly with seals installed meets IP ingress claims, and validate with a sample in your enclosure to confirm real-world performance under pressure-wash and dust conditions.
Where can engineers confirm mechanical drawings and part status for 64319-3211? +
Consult the original manufacturer’s product pages and the official datasheet for normative mechanical drawings, material callouts, and active lifecycle status. Request the latest sales drawing and qualification reports from the manufacturer to ensure fit, finish, and current availability.