503480-0800 datasheet: full electrical & mechanical specs
The 503480-0800 datasheet identifies an 8-position FFC/FPC right-angle SMT connector with 0.50 mm pitch, a voltage rating of 50V AC/DC, and an operating range from −40°C to +85°C. This technical guide distills essential electrical, mechanical, and PCB footprint data for rapid engineering validation.
Background & Part Overview
Part Function & Common Uses
Core Function: This connector serves as an FFC/FPC receptacle designed for signal and low-power flex-to-board interconnects. Application Context: Featuring 8 positions and a 0.50 mm pitch, it is ubiquitous in display, camera, and sensor flex cables. Design Impact: For compact consumer or industrial PCBs, the right-angle SMT mounting minimizes the vertical profile and routes flexes parallel to the board edge, optimizing space in mobile devices and high-density sensor assemblies.
Key Summary Specs at a Glance
| Parameter | Technical Value |
|---|---|
| Positions | 8 |
| Pitch | 0.50 mm |
| Termination | SMD / SMT |
| Contact Style | Dual contact |
| Voltage Rating | ≈ 50 V AC/DC |
| Housing Material | Liquid Crystal Polymer (LCP), UL94 V-0 |
Full Electrical Specifications
Electrical Ratings & Limits
The electrical ratings establish safe operating envelopes for hardware design. According to the datasheet, the part is rated for approximately 50V and provides specific limits for insulation resistance and dielectric strength. Designers must apply appropriate derating factors for environments with elevated temperatures or high vibration to maintain long-term reliability.
Signal Integrity & Performance
Dual-contact terminations significantly reduce contact resistance compared to single-leaf designs. However, the 0.50 mm pitch and short mating length may limit high-speed impedance-controlled routing. For multi-hundred-megabit signaling, ensure return paths remain continuous and trace stubs are minimized.
Full Mechanical Specifications
Dimensional Tolerances
The 503480-0800 datasheet specifies critical tolerances for seat height, pin length, and board standoff, typically held within sub-0.1 mm. During DFM, verify solder fillet clearance and pick-and-place nozzle compatibility to ensure reliable high-volume manufacturing.
Materials & Plating
Utilizing LCP (Liquid Crystal Polymer) for the housing ensures dimensional stability during high-heat reflow cycles. Contacts are constructed from copper alloy with tin plating. Note: Tin plating is cost-effective but may require additional corrosion protection in high-humidity environments.
Mounting, Footprint & Assembly Guide
PCB Footprint & Soldering
Correct land pattern design is vital for joint integrity. Use rectangular pads matched to the 0.50 mm pitch. We recommend a 60–80% solder paste coverage to prevent bridging or excess solder. Polarity markers and fiducials should be placed for consistent pick-and-place orientation.
Reflow Profile & Inspection
The LCP housing is compatible with standard lead-free reflow profiles. Post-assembly inspection should focus on coplanarity, adequate fillet formation at the leads, and the absence of "tombstoning." Functional mating checks are recommended to confirm the integrity of the dual-contact interface.
Selection Checklist & Real-World Use
Quick Engineering Checklist
- ✔ Confirm 8 positions and 0.50 mm pitch matches your flex cable.
- ✔ Validate voltage/current needs (Ideal for
- ✔ Check housing height and standoff against the enclosure mechanical constraints.
- ✔ Verify plating (tin) suitability for the application's environment.
Summary
This 503480-0800 breakdown delivers critical data for rapid validation. Key takeaways include:
- • Configuration: 8-position, 0.50 mm pitch, right-angle SMT for tight flex-to-board routing.
- • Electrical: Rated for ≈50V; requires derating for harsh thermal conditions.
- • Mechanical: Rugged LCP housing with tin-plated contacts; demands precise reflow control.